Market Launch in 2027

Mega Power DC

Containerized Data Centers
Built for Speed and Scale

Hyperscale from 125 Units

Mega Power DC

Highly Configurable with ESS options.

Deploy data centers quickly.

10ft Modular Data Centers

Made by PowerX in Japan

Configuration

 

Integrated

ESS

(~800kWh)

4-6 IT racks

ESS: Energy storage systems

IT racks: 42U

Lower

Cost

~25%

lower CapEx

compared to conventional data centers

Faster

Deployment

~1 year

vs. 4–5 years for building-type data centers

Cutting Edge Technology in A Small and Efficient Footprint

Closed-Loop Liquid Cooling for High Efficiency and Stability

As server performance and rack power densities continue to increase, data centers require more precise and reliable cooling. Mega Power DC is purpose-built with a dedicated liquid-cooling architecture to maintain stable temperature control in high-density, high-heat environments.

Drawing on our expertise as a battery manufacturer, we apply advanced thermal design to deliver uniform cooling, ensuring continuous operation and improved energy efficiency.

megapowerdc-cooling

Space-Efficient Design in a 10ft Container

All essential data center functions are integrated into a compact 10ft container, minimizing space requirements and enabling fast deployment in constrained locations.

Installed rather than built, Mega Power DC delivers speed, cost efficiency, and greater flexibility compared to traditional data center construction.

megapowerdc-space

Maximizing Power Efficiency with Direct Current

Power efficiency directly impacts both operating costs and environmental performance in data centers. Mega Power DC is designed with DC power delivery as the default, while supporting both AC and DC server configurations.

Direct DC power reduces conversion losses and heat generation, lowering overall energy consumption. Combined with integrated energy storage, this architecture supports high-density deployments and reliable, long-term operation.

megapowerdc-ess

Manufactured at Scale at Our Okayama Factory

From 2027

※Lead times are subject to order volume.

Deploy quickly with minimal cost

Building vs. Container

Cost Advantage

~25%

Lower Cost

Cost comparison

(per MW of Power Capacity, IT equipment excluded)

Conventional Large-Scale DC: ¥2.47 billion
Mega Power DC: ¥1.77 billion

Unmatched Lead Times

Deploy in stages, as energy is available. Due to it's modularity, data centers can be scaled as energy resources become available.

工期の比較(例)

一般的なプロセス:基本設計 > 開発許可確認 / 地元折衝 > 系統連系、機器調達 / 本設計(土木・建屋・電気)〜許可取得〜建設工事+試運転 >>> 運転開始まで 約4〜5年

Mega Power DC:基本設計 > 自治体確認 > 本設計(電気・土木)/ 生産・出荷 / 設置工事+試運転 >>> 工期の圧縮 = コストインパクト >>> 運転開始まで 約1年+α

Everything from Edge to Hyperscale

Hyperscale from 125 Units

Data Center Power

50 MW

Number of Containers

250

Number of IT Racks*1

1,500

Alternative to Traditional Data Centers

A superior solution to the high construction costs and long lead times of conventional builds.

Estimated Site Area: ~1 ha

High-density deployment designed to maximize capacity on limited land.

Connected to Large-Scale Power Sources

Leveraging existing large-scale power infrastructure, such as thermal power plants.

Data Center Power

25 MW

Number of Containers

125

Number of IT Racks*1

1750

Powered as an Internal Load of Existing Power Plants

Stable power supplied directly from neighboring facilities, minimizing transmission losses.

Space-Efficient & Relocatable

Efficient internal layout reduces footprint, and containerized units can be relocated during plant expansion or redevelopment.

Energy Storage for Thermal Power Load Balancing

Integrated energy storage enables economic charge/discharge operation and supports stable plant operation, including during inspections and maintenance.

Integrated with Battery Power Plants

Additional capacity can be deployed on-site, with containerized batteries added or replaced as needed.

Data Center Power

0.2~2 MW

Number of Containers

1~10

Number of IT Racks*1

6~60

Faster Grid Connection

Energy storage mitigates grid constraints, enabling earlier system interconnection.

Renewable Power Utilization

High-power IT workloads can be operated using carbon-free electricity.

Integrated Energy Arbitrage

Coordinated operation of data center (bit) and energy storage (watt) enables optimized economic returns.

Deployed as Edge & On-Site Data Centers

Utilizes available space in urban areas or on-site locations to expand edge computing capacity.

Data Center Power

0.2 MW

Number of Container

1

Number of racks*1

4

Demand-Driven, Site-Integrated

Ideal for physical AI and private AI deployments, delivering low-latency performance.

Battery-Backed Power Supply

Backup power via integrated batteries, supporting BCP for IT and AI workloads.

Urban, Space-Efficient Deployment

Efficient use of limited land and compact sites.

*The planned number of racks is as follows: With integrated battery storage: 4 IT racks. Without battery storage: 6 IT racks

Scalable, Mass-Produced Designs Customized to Your Needs

Example Configurations:GPUCPUStorageESS (Battery)

Example Specifications

AI Data Center Configuration

※The specifications below are an example system configuration.Final specifications can be customized to meet customer requirements. Contact us for details.


Compute Performance

Rack configuration (42U): 4–6 racks. Modular expansion up to 160 GPUs

Performance: 633 PFLOPS (H200 / FP8)

Inference capacity:~20 instances, 80K tokens/sec, ~800 concurrent users (reference)


Energy Storage Capacity (Optional)

Modular expansion from full DC configuration up to 800 kWh


Cooling / Thermal Management

Proprietary integrated liquid-cooling system

Scales with energy and compute density & supports up to 150 kW per rack (depending on requirements)


Fire Protection & Detection

ESS: NFPA 855A–compliant (UL 9540A test assumed)

Compute area: Clean agent suppression (Novec™ 1230)

Detection: VESDA + smoke + heat + gas (H₂, CO) detection


Networking / Interconnection

100G~400G Ethernet、NVLink、RoCEv2、InfiniBand


Certifications & Standards (Target)

BESS:IEC 62619 / JIS 8715、UL 9540A

Power System:UL 1741

DC:EN 50600、TIA-942、IEC 22237、ASHRAE TC 9.9


Enclosure

ISO 10ft High-Cube Container


Ingress Protection (IP Rating)

IP55 (standard) / IP65 (optional, selectable based on installation environment)